Home Community B-Hyve Indoor/Outdoor Timer Rain sensor not functioning solved for Rain Bird WR2 wireless sensor Reply To: Rain sensor not functioning solved for Rain Bird WR2 wireless sensor

#4475
Toolmaker
Participant

I found my above solution to be incorrect! To get the sensor to function properly with the control I had to connect the red wire from the sensor to the terminal on the right side of the 24 VAC out (which if measured with a volt meter is 24 VAC to com). I then connected the black wire to the COM terminal (just to the right of the sensor terminals). Things seem to be functioning correctly when creating a bypass condition on the sensor, now I need a rain event to really test it!